Details
QI-300-I
CURRENT TRANSFORMER AC/DC LOOP POWERED
The QI-300-I is a AC/DC current transformer, galvanically isolated from the measuring circuit. The device is in the function and appearance very similar to a standard active TA, however, able to measure the DC component and AC RMS. The transformer is powered 4-20mA current loop and therefore does not require a direct power supply. It ‘s the first Hall’s effect current transformer loop-powered with 0.5% accuracy on the market.DIN rail mounting instructions:
To mount the hooks on QI. If you want to mount horizontally, use the flexibility of hook to catch into prepared by pressing the center of the clip. For vertical mounting, slide the hooks into the slots, external holding the two tabs on the clip . Fig. 6 For mounting on DIN rail horizontally, once hooked on the bottom, push with both hands. For vertical mounting on DIN rail, once hooked on the bottom, push with both hands on the hooks. To release from DIN rail, use a screwdriver and lever up to release the fins.CAUTION: Magnetic fields of high intensity can vary the values measured by the transformer. Avoid installation near permanent magnets, electromagnets or iron masses that induce strong changes in the magnetic field. If any irregularity recommend reorient or move the transformer in the area most appropriate.
POWER SUPPLY | Passive loop powered, 11...30Vdc, Protections against polarity reversal and overtemperature. |
---|---|
ABSORPTION | Less then 3,5mA |
PROTECTION INDEX | IP20 |
ACCURACY | 0,5% F.S |
RESOLUTION | 12 bit |
TEMPERATURE COEFFICIENT | < 200 ppm/°C |
WORKING TEMPERATURE | -15...+65°C |
STORAGE TEMPERATURE | -40°C... +85°C |
RESPONSE TIME | 1000 ms |
TYPE OF MEASURE | RMS (monopolar) or DC |
RANGE | 300 Arms or 150 Arms dip-switch setting, bipolar (+/- 300A DC o +/-150A DC) |
OUTPUT | 4...20 mA |
BAND WIDTH AT -3dB | DC or 20...2000 Hz |
ISOLATION | 3 kV on bare wire |
OVERLOAD | 2000 A pulse, 500A continuos |
CREST FACTOR | 1,4 |
HYSTERESIS | 0,2% f.s |
HUMIDITY | 10...90% not condensing |
ALTITUDE | Up to 2000 m s.l.m |
WEIGHT | 370 g. |
FILLING | Epoxy Resins |
BOX MATERIAL | PBT, gray |
MOUNTING | Screw predisposition for vertical/ horizontal mounting, DIN Rail clips (included) for vertical/horizontal mounting |
TERMINAL | Removable terminals 5,08mm |
DIP-SWITCH | 2 poles |
LED | N°1 yellow ( Power on ) |
STANDARDS CE | EN55022: 2010-12; EN55024: 2010-11; |
DIMENSIONS | 6,1x 63x 26,4 mm (terminal excluded) |
High accuracy, yet very cost effective split-core AC/DC current transformers supplier in Malaysia & Singapore. Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.
Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.
Saturn Pyro provides reliable engineering services such Electrical Safety Survey, Power System Studies (Short Circuit, Load Flow & Protection Discrimination on ETAP), Arc Flash Assessment & Labeling, Design Of Earthing & Lightning Protection, Measurement Of Touch & Step potentials, Power Quality Management, Energy Audit and Data Center Performance Assessment. We also provides Electrical Safety Survey such as Inspection of an electrical installation, Identification of risk (electrical hazards), Review of documentation, operations & maintenance procedures, contingency planning, Generation of report in details of risk potentials and plan for mitigation, Closing report post implementationas. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.
Ketepatan tinggi, pembekal pengubah arus AC/DC teras pembahagi yang sangat berkesan dari segi kos di Malaysia & Singapura. Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.
Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.
Saturn Pyro menyediakan perkhidmatan kejuruteraan yang boleh dipercayai seperti Tinjauan Keselamatan Elektrik, Kajian Sistem Kuasa (Litar Pintas, Diskriminasi Aliran Beban & Perlindungan pada ETAP), Penilaian & Pelabelan Denyar Arka, Reka Bentuk Pembumian & Perlindungan Kilat, Pengukuran potensi Sentuhan & Langkah, Pengurusan Kualiti Kuasa , Audit Tenaga dan Penilaian Prestasi Pusat Data. Kami juga menyediakan Tinjauan Keselamatan Elektrik seperti Pemeriksaan pemasangan elektrik, Pengenalpastian risiko (bahaya elektrik), Semakan dokumentasi, prosedur operasi & penyelenggaraan, perancangan kontingensi, Penjanaan laporan dalam butiran potensi risiko dan rancangan untuk mitigasi, Pos laporan penutup perlaksanaan. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.
View more about QI-300-I Current Transformer on main site