Circutor CVM-B50 Three-Phase Power Analyzer
Product Description
The Circutor CVM-B50 is a three-phase power analyzer and multifunction electrical energy meter designed for panel-door installation in switchboards, distribution panels and electrical monitoring systems. The CVM-B50 provides a complete view of electrical consumption and power quality parameters, measuring voltage, current, active power, reactive power, apparent power, power factor, frequency, energy and harmonic distortion from a single compact panel-mounted instrument.
Designed for three-phase electrical systems, the Circutor CVM-B50 displays electrical measurements directly on its high-contrast backlit display, allowing operators, electrical contractors and energy managers to view measurements locally at the switchboard without requiring a laptop or external monitoring system. The display provides information for the three phases and total values, making it suitable for day-to-day electrical inspection, energy monitoring and troubleshooting.
The CVM-B50 supports measurement of phase-to-phase and phase-to-neutral voltages, currents, active power, reactive power, apparent power and power factor, together with frequency and harmonic measurements. Its harmonic analysis and THD measurement capabilities help identify electrical distortion and assess the quality of the power supply, particularly in installations containing variable speed drives, rectifiers, power electronics, UPS systems and other nonlinear loads.
A key feature of the CVM-B50 is its ability to measure four-quadrant energy, allowing imported and exported energy to be monitored separately. This makes the analyzer suitable for installations where electrical energy can flow in both directions, including solar PV systems, generators, renewable energy installations, energy storage systems and sites with both consumption and generation.
The CVM-B50 also provides Modbus communications, enabling measured electrical parameters to be transmitted to an energy management system (EMS), building management system (BMS), SCADA platform, PLC or other industrial monitoring software. This allows the device to function as both a local panel meter and a data source for centralized energy monitoring and reporting.
The analyzer is designed for panel-door mounting, making it particularly suitable for electrical switchboards and distribution panels where space is limited and measurements need to remain visible to operators. Its rear connection terminals keep wiring behind the panel while the display and navigation controls remain accessible from the front.
The CVM-B50 is suitable for sub-metering, energy monitoring, load profiling, power factor monitoring, harmonic monitoring, electrical distribution monitoring, energy cost allocation and ISO 50001 energy-management applications.
For commercial buildings, industrial facilities, data centres, utilities, manufacturing plants, water and process facilities, solar installations and other energy-intensive sites, the CVM-B50 provides a practical way to understand where electrical energy is being consumed, how equipment is loading the supply and whether power-quality issues are affecting the installation.
Key Features
- Circutor CVM-B50
- Three-phase power analyzer
- Multifunction electrical energy analyzer
- Panel-mounted power meter
- Panel-door electrical analyzer
- Three-phase electrical measurement
- Voltage measurement
- Current measurement
- Active power measurement
- Reactive power measurement
- Apparent power measurement
- Power factor measurement
- Frequency measurement
- Energy measurement
- Four-quadrant energy measurement
- Imported and exported energy
- Harmonic analysis
- THD measurement
- Power-quality monitoring
- Backlit display
- Multi-phase display
- Modbus RTU communication
- Energy management system integration
- SCADA integration
- BMS integration
- Expandable modules
- Panel-mount installation
Applications
The CVM-B50 can be used for:
- Electrical energy monitoring
- Three-phase energy monitoring
- Sub-metering
- Industrial energy monitoring
- Commercial building energy monitoring
- Switchboard monitoring
- Distribution board monitoring
- Electrical panel monitoring
- Load monitoring
- Load profiling
- Energy cost allocation
- Power factor monitoring
- Harmonic monitoring
- THD monitoring
- Power-quality assessment
- Generator monitoring
- Solar PV monitoring
- Renewable energy monitoring
- Import/export energy monitoring
- Data centre energy monitoring
- Factory energy monitoring
- Manufacturing plant monitoring
- Water treatment energy monitoring
- Process plant monitoring
- HVAC energy monitoring
- ISO 50001 energy management
- Energy management systems
- SCADA energy monitoring
- BMS energy monitoring
Typical Applications
Sub-Metering
Install the CVM-B50 on a factory line, building tenancy, HVAC system, production area or other electrical load to measure actual energy consumption rather than relying on estimated or aggregated data.
Energy Cost Allocation
Measure individual feeders, departments, production lines or tenants to determine how electricity consumption is distributed across a facility.
Four-Quadrant Energy Measurement
Monitor both imported and exported energy in installations with generation, such as solar PV, generators and renewable energy systems.
Power Factor Monitoring
Monitor power factor alongside voltage, current and power to identify inefficient electrical loading and potential reactive-power issues.
Harmonic and THD Monitoring
Use harmonic measurements to identify electrical distortion caused by nonlinear loads, variable frequency drives, rectifiers, UPS equipment and power electronic devices.
Centralized Energy Monitoring
Transmit measurements through Modbus to an EMS, BMS, SCADA system or industrial energy platform for centralized monitoring, dashboards, reporting and analysis.
SEO Keywords
Circutor CVM-B50, CVM B50, Circutor CVM B50 power analyzer, CVM-B50 power meter, CVM-B50 energy analyzer, Circutor three phase power analyzer, Circutor energy analyzer, three-phase power analyzer, three-phase energy meter, multifunction power meter, multifunction energy analyzer, panel mount power analyzer, panel door power analyzer, electrical panel meter, switchboard power meter, three phase electrical meter, three phase energy monitoring, electrical energy analyzer, power monitoring meter, energy monitoring meter, active reactive apparent power meter, power factor meter, frequency meter, harmonic analyzer, THD meter, harmonic distortion analyzer, four quadrant energy meter, import export energy meter, bidirectional energy meter, Modbus power meter, Modbus energy analyzer, RS-485 energy meter, SCADA power meter, BMS energy meter, energy management meter, sub-metering power analyzer, industrial power analyzer, commercial energy meter, Circutor energy monitoring.
Long-Tail Search Terms
- Circutor CVM-B50 three phase power analyzer
- Circutor CVM-B50 energy meter
- Circutor CVM B50 multifunction power meter
- three-phase panel mount power analyzer
- three-phase electrical energy analyzer with Modbus
- panel door three-phase energy meter
- three-phase power meter with harmonic analysis
- three-phase power analyzer with THD measurement
- four quadrant three-phase energy meter
- import export energy meter for solar systems
- bidirectional energy meter for solar PV
- Modbus three-phase power analyzer
- RS-485 three-phase energy meter
- industrial three-phase power monitoring meter
- electrical switchboard power analyzer
- electrical distribution panel energy meter
- power factor and harmonic analyzer
- three-phase voltage current power energy meter
- energy monitoring meter for ISO 50001
- power analyzer for energy management systems
- three-phase sub-metering power analyzer
- commercial building energy monitoring meter
- industrial energy monitoring power meter
- three-phase load monitoring analyzer
- electrical panel harmonic monitoring meter
Meta Description
Circutor CVM-B50 three-phase power analyzer with voltage, current, power, energy, power factor, harmonics, THD, four-quadrant energy and Modbus communication.
FAQs
What is the Circutor CVM-B50?
The Circutor CVM-B50 is a three-phase multifunction power analyzer for measuring electrical parameters including voltage, current, power, energy, power factor, frequency and harmonics.
What does the CVM-B50 measure?
It measures voltage, current, active power, reactive power, apparent power, power factor, frequency, energy and harmonic distortion.
Does the CVM-B50 measure harmonics?
Yes. The CVM-B50 provides harmonic analysis and THD measurement for monitoring electrical distortion.
Does the CVM-B50 support four-quadrant energy measurement?
Yes. Four-quadrant measurement allows imported and exported energy to be monitored, making it suitable for sites with generation such as solar PV.
Does the CVM-B50 support Modbus?
Yes. The CVM-B50 provides Modbus communication for connecting measurements to energy management, SCADA, BMS and other monitoring systems.
Where is the CVM-B50 installed?
It is designed for panel-door installation, particularly in switchboards, distribution boards and electrical control panels.
Saturn Pyro
44 & 44A, Jalan Palma Rafis 1, Taman Dato Chellam, 81800 Ulu Tiram, Johor
Tel: 07 8660 510 Fax: 07 8660 511 Email: enquiry@saturnpyro.com
Aug 19,2026