Split Core CT (Bolt-On Type) SPD Series - 3000/5A, Class 1
Specifications
Details
Split Core CT - Bolt-On Type
The SPD Series bolt-on split core current transformer is designed for current measurement in new and existing electrical networks. It can be opened and installed around existing cables or busbars without disconnecting the primary circuit, reducing shutdown time, installation work and wiring modification.
This 500/5A class model range is suitable for energy metering, sub-metering, power monitoring, EMS, BMS, SCADA, digital power meters, energy analyzers, IoT gateways and IoTWatt 4.0 energy monitoring systems.
Applications
Energy Metering
Suitable for metering and sub-metering of LV feeders, incomers and distribution panels.
Energy Management
Used with EMS, BMS, SCADA and IoTWatt 4.0 for energy monitoring and reporting.
Control & Monitoring
Provides current input signals for power meters, relays and monitoring devices.
Retrofit Projects
Can be installed without opening the cable or busbar primary circuit.
Specifications
| Specification | SPD Series Bolt-On Split Core CT |
|---|---|
| Rated Current | 3000A for this model page |
| Secondary Output | 5A or 1A |
| Accuracy | 0.5% to 1% from 10% to 150% of full scale range |
| Rated Test Voltage | 3kV AC for 1 minute |
| Rated Short-Time Thermal Current | 60In |
| Rated Dynamic Current | 2.5Ith |
| Rated Voltage | 0.72kV AC |
| Operating Temperature | -10°C to +50°C |
| Housing Rating | UL 94V0 |
| Safety Factor | FS 5 |
Dimension and Product Images


Model Selection Table
| Model | Outer Dimension (mm) | Window Size (mm) | Installation Size (mm) | CT Ratio | Burden | ||||
|---|---|---|---|---|---|---|---|---|---|
| L | W | H | a | e | M | N | |||
| SPD-XH-30x20 | 90 | 40 | 110 | 20 | 30 | 49 | 52 | 100/5 ~ 400/5 | 1VA ~ 2.5VA |
| SPD-XH-80x50 | 115 | 37 | 156 | 50 | 80 | 81 | 50 | 250/5 ~ 1000/5 | 1.5VA ~ 5VA |
| SPD-XH-80x80 | 145 | 37 | 159 | 80 | 80 | 111 | 45 | 250/5 ~ 1000/5 | 1.5VA ~ 5VA |
| SPD-XH-120x80 | 145 | 37 | 200 | 80 | 120 | 111 | 45 | 500/5 ~ 1500/5 | 2.5VA ~ 7.5VA |
| SPD-XH-160x80 | 185 | 53 | 248 | 80 | 160 | 118 | 45 | 1000/5 ~ 3000/5 | 10VA ~ 15VA |
Typical Use with Energy Monitoring Systems
SPD Series bolt-on split core CTs are commonly used with digital power meters and energy analyzers for retrofit current measurement. They are suitable for feeder monitoring, main incomer monitoring, tenant sub-metering, demand monitoring and IoT-based energy data collection.
- Digital power meters and energy analyzers
- Energy metering and sub-metering panels
- EMS, BMS and SCADA integration
- IoT gateway and remote energy monitoring projects
- IoTWatt 4.0 Digital Energy Audit and energy analytics
SPD Series Bolt-On CT Supply and Integration
Saturn Pyro supplies SPD Series bolt-on split core CTs, digital power meters, IoT gateways and complete energy monitoring integration for industrial and commercial sites in Malaysia. These CTs can be used with power meters, EMS, BMS, SCADA and IoTWatt 4.0 for energy monitoring, sub-metering and digital energy audit applications.
Enquire NowView more about Split Core CT (Bolt-On Type) SPD Series - 3000/5A, Class 1 on main site