CIRCUTOR Panel Mounted Power Quality Analyzer

CVM-A1500 Power Quality Analyzer

CVM-A1500 is a panel-mounted power quality analyzer designed for critical electrical installations where continuous energy monitoring, waveform capture, event recording and power quality visibility are required.

It includes an integrated Energy Management Software environment and an internal HTML5 web server, allowing users to monitor the installation locally or remotely using a standard web browser.

IEC 61000-4-30 Class A EN 50160 PQ Variables Swells / Dips / Interruptions Transient Capture Waveform Recording Web Server + EMS
CIRCUTOR CVM-A1500 Power Quality Analyzer
Panel Format 144 x 144 mm panel-mounted analyzer
Power Quality Events, transients, harmonics, flicker and unbalance
Connectivity Ethernet web server + RS-485 Modbus RTU / BACnet
Integration SCADA, PowerStudio, IoTWatt 4.0 and energy dashboards

Overview: Advanced Power Quality and Energy Monitoring

CVM-A1500 is designed to be installed at the most relevant or critical point of an electrical installation. It records and monitors a wide range of electrical variables, including RMS, maximum and minimum values, energy data and power quality events.

The analyzer captures swells, dips, interruptions every half cycle and transients according to IEC 61000-4-30 Class A requirements. When an event occurs, the device records the voltage and current waveform so that the disturbance can be reviewed with proper evidence.

Key positioning

CVM-A1500 is suitable for main incomers, critical feeders, production facilities, semiconductor plants, data centres, hospitals, airports and other installations where electrical disturbance visibility is important.

Power Quality Investigation Workflow

CVM-A1500 converts electrical disturbances into usable evidence for engineering analysis, compliance reporting, maintenance action and long-term power quality improvement.

1. Monitor Continuously measure voltage, current, energy and network quality variables.
2. Capture Record swells, dips, interruptions, transients and waveform data.
3. Classify Display event details in CBEMA, ITIC and SEMI-F47 graphs.
4. Integrate Connect to web browser, SCADA, PowerStudio or IoTWatt 4.0.
5. Improve Use evidence for root cause analysis, mitigation and reliability improvement.

Key Features

PQ

Class A Power Quality

Registers swells, dips, interruptions and transients according to IEC 61000-4-30 Class A.

WAV

Waveform Capture

Captures voltage and current waveform associated with power quality events and transients.

H63

Harmonics up to 63rd

Measures voltage and current harmonic decomposition up to the 63rd harmonic.

WEB

Integrated Web Server

HTML5 web server allows installation control using a standard browser without dedicated local software.

EMS

Energy Management Software

Integrated EMS supports historical data registration, analysis and energy management review.

I/O

Expandable I/O

Expandable up to 3 modules for additional inputs, outputs and communication interfaces.

Power Quality Visibility

CVM-A1500 measures key power quality variables defined in EN 50160, including flicker, unbalance coefficient, asymmetry coefficient and harmonic decomposition. It also provides oscilloscope-style real-time waveform viewing for voltage and current.

Swells Dips Interruptions Transients Voltage waveform Current waveform Flicker Unbalance Kd Asymmetry Ka Harmonics up to 63rd CBEMA graph ITIC graph SEMI-F47 graph

Technical Highlights

Metering and Power Quality

Analyzer TypePanel-mounted power quality analyzer
Panel Size144 x 144 mm
Measurement Channels5 voltage channels + 4 ITF current channels
Power Quality StandardIEC 61000-4-30 Class A
Energy AccuracyActive energy Class 0.2S according to IEC 62053-22
HarmonicsVoltage and current harmonics up to 63rd order

Display and Interface

DisplayHigh-definition VGA colour display
Custom Screens5 user-customisable screens
Web ServerIntegrated HTML5 web server
OscilloscopeReal-time instantaneous waveform display
Front ProtectionIP65 with airtight seal

Communications and Software

EthernetWeb server access and integration
RS-485Modbus RTU or BACnet protocol
SCADA IntegrationXML requests and communication protocols
PowerStudioConnection to save and store information in server or PC
Redundant StoragePowerStudio support helps avoid local memory limits

I/O, Tariff and Power Supply

ExpansionExpandable up to 3 modules
Tariffs3 tariffs selectable by digital input or communications
Outputs2 relay outputs + 2 transistor outputs
Digital Inputs2 digital inputs for tariff, logic state or pulse centralisation
Power SupplyUniversal switching power supply AC/DC or DC

Main Applications

Critical Incomer Monitoring

Monitor incoming supply quality, energy, demand and disturbance behaviour at main distribution panels.

Power Quality Investigation

Capture dips, swells, interruptions, transients and waveform evidence for root cause analysis.

Industrial Reliability

Support production continuity by identifying events that affect sensitive equipment and automation systems.

Energy Management

Record historical energy data, cost, kgCO2 emissions and tariff-based consumption.

SCADA and BMS Integration

Use Ethernet, RS-485, XML and protocol support for integration into plant monitoring systems.

Alarm and Control

Use relay and transistor outputs for alarms, pulses, load control and operational signalling.

Alarm, Pulse and Control Functions

Function Capability
Programmable Alarms 4 alarms using 2 transistor outputs and 2 relay outputs, independently programmable.
Alarm Logic Low or high value setting, hysteresis, connection and disconnection delay, NO/NC standby status and interlocking.
Pulse Outputs Transistor outputs can generate impulses based on energy, cost, kgCO2, total meter or tariff hours.
Transducer Function Can convert analogue signals to instantaneous parameters when suitable analogue output expansion modules are used.
Process Signal Display Analogue input expansion modules allow process signals to be displayed and reported to SCADA systems.
Datalogger Integrated datalogger with web server and XML for historical data logging.

Expansion Modules

CVM-A1500 can be expanded with communication, input and output modules to suit plant monitoring, SCADA integration, alarm control, pulse input collection and process signal applications.

M-CVM-AB-8I-8OTR M-CVM-AB-8I-8OR M-CVM-AB-4AI-8AO M-CVM-AB-Modbus TCP M-CVM-AB-MBus M-CVM-AB-LonWorks M-CVM-AB-Profibus

IoTWatt 4.0 Integration Use

CVM-A1500 can be used as a high-value data source for IoTWatt 4.0 where permanent power quality, energy and disturbance monitoring is required. The device can provide data for main incomer monitoring, power quality dashboards, energy analytics, anomaly investigation, demand review and digital energy audit workflows.

Practical use with IoTWatt 4.0

Deploy CVM-A1500 at critical feeders or main incomers, use its local web server and PQ event logging for engineering evidence, and integrate the energy and PQ data into IoTWatt 4.0 for dashboards, reports, alerts and long-term energy efficiency improvement.

CVM-A1500 Supply, Integration and Power Quality Engineering

Saturn Pyro supplies and supports CIRCUTOR CVM-A1500 power quality analyzers for industrial energy monitoring, critical feeder monitoring, PQ event investigation, SCADA integration and IoTWatt 4.0 digital energy audit applications across Malaysia.

Contact Us

View more about CVM-A1500 Power Quality Analyzer on main site